400-627-1108Mobile station
|Chinese|English

Product

Current Position:Home > Product > Oil Testing Instrument

Product details

TKSPYOil Dissolved Gas Analyzer

Other name:hydrogen generator、full-automatic hydrogen generator

Specification Certificate of identification Service promise

Current limiting protection Power amplifier protection Voltage short circuit protection Open circuit protection Thermal protection of power amplifier

Note:Regarding product purchase, technical maintenance and other services, welcome to send email:

IntroductionParametersAccessoriesService

Product Introduction

Chromatographic analysis technology is a kind of separation and analysis technology of multi-component mixture. It mainly makes use of the difference of boiling point polarity and absorption add coefficient of each component in the sample in the chromatographic column so that each component can be separated in the chromatographic column and detect the separated components by detection apparatus so as to conduct qualitative and quantitative analysis of multi-component mixture.

Because this method has a high separation efficiency fast analysis less sample consumption etc therefore has been widely used in petrochemical biochemical medicine and health food of the health and quarantine inspection of environmental protection industry in the medical clinical departments by gas chromatography in the field of solve the industrial production of intermediates and pollution detection of industrial products quality inspection scientific research production control and other issues.

Chromatographic instrumentIt is a kind of high cost performance multi-function economical and practical precision instrument which adopts three-column and three-gas circuit operating system. The basic type is equipped with hydrogen flame ionization detection (FID) and thermal conductivity detection device(TCD).

Chromatographic instrumentUsing microcomputer and integrated circuit control English and Chinese interface high degree of self-motion and good reliability operating parameters keyboard setting instrument with power failure protection file storage and call function instrumentLarge screen liquid crystal display,The detection apparatus and its control assembly unit adopt plug and play control modesimplicity of operator for the instrument to conduct constant temperature and program temperature rise operation column room is equipped with flexible rear door self-motiontemperature control system the column box has excellent performance high precision temperature control quick rise and drop speed and flexible air temperature operation process Reliable easy to expand suitable for a variety of detection and sample combinations.

The detector adopts the unitized combination design which is easy to install and maintain. The chromatograph can be configured with a variety of detectors (TCD FID ECD FPD and NPD). According to the user's analysis needs the chromatograph can be configured with up to four detectors at the same time.

The chromatograph's injection system can be equipped with a variety of injection devices such as filling column head injection glass lining rapid injection and capillary column divided/undivided injection with diaphragm cleaning function.

Product nickname:hydrogen generator、full-automatic hydrogen generator、self-motionHydrogen generator、chromatographic instrument


Product Characteristics

  • 1.Adopt the technologically advanced 10/100m adaptive Ethernet communication interface and built-in IP protocol stack so that the instrument can easily realize long-distance data transmission through enterprise Intranet and Internet; It is convenient to set up the laboratory simplify the configuration of the laboratory and facilitate the management of the analysis data.
  • 2.Chromatograph internal design process of three separate connection can connect to the local processing site (laboratory) unit director (such as quality inspection section chief production factory director etc.) and supervisor (e.g. environmental protection bureau bureau of technical supervision etc.) you can easily make unit director and supervisor real-time monitoring instrument is running and analysis data.
  • 3.The NetChromTM workstation can support multiple chromatographs at the same time realizing data processing and control simplifying document management and effectively reducing the laboratory investment and operating costs of users.
  • 4.The system has Chinese and English operating systems users can switch according to the need.
  • 5.The temperature control area can be named freely by the user for convenience.
  • 6.The chromatograph adopts multi-processor parallel operation which makes the instrument more stable and reliable. It can meet the requirements of complex sample analysis. It can be equipped with a variety of high-performance detectors such as FID TCD ECD FPD and NPD. Up to four detectors can be installed at the same time. The detector can also be added after the purchase of the instrument is very convenient to choose and install other detectors.
  • 7.The chromatograph adopts modular structure clear design easy to replace and upgrade protecting the effectiveness of the investment.
  • 8.New microcomputer temperature control system high temperature control accuracy reliability and anti-interference performance; With a six-way completely independent temperature control system it can realize 16 steps of programmed temperature rise so that the equipment can be competent for a wider range of sample analysis; With the automatic rear door system of the column box the low temperature control precision can be improved and the rise/drop speed is faster.
  • 9.The chromatograph can be matched with advanced electronic flow controller (EFC) and electronic pressure controller (EPC) to realize digital control which can greatly improve the reproducibility of qualitative and quantitative results.
  • 10.The chromatograph is designed with timing and self-starting program which can easily complete the on-line analysis of gas samples (equipped with on-line automatic sample injection unit).
  • 11.The operation system of keyboard controlled by microcomputer is simple and convenient. And design detector automatic identification technology. With the function of fault diagnosis and power off data protection it can set parameters automatically by memory
  • 12.The chromatograph has built-in low noise high resolution 24-bit AD circuit and has the function of baseline storage and baseline deduction.
  • 13.Collect chromatographic signal and data processing suitable for Windows xp Windows 2000 Windows7 and other operating systems. Sample data is read into CDF files that conform to A/A (American analytical society) standards so they are compatible with chromatography workstations such as Agilent and Waters.
  • 14.Chromatography system with full intellectual property rights MODBUS/TCP standard interface and DCS can be easily connected.
  • 15.Chromatographs and a number of manufacturers at home and abroad to produce automatic injector docking; Such as aoc-20i of jimazu HT series of high speed liquid and gas automatic sampler of Italian HTA company.
  •  

Product Parameter

Key Technical Indexes

Operating display 192×64 lattice sinicized liquid crystal
Temperature control domain district 6 route
Temp Range indoor temperature+5℃~400℃, increment :1℃,precision:±0.1℃
Temperature program order 16steps
Cheng Sheng rate 0.1~40℃/min
Pneumatic control mechanical valve control mode electronic pressure flow control mode any optional
External event 4 route
Sample injector species fill column capillary six way valve gas injection automatic headspace injection etc optional
Detectionconfigured 5Entries,FID、TCD、ECD、FPD、NPD(optional)
Start the sample manual self-motion any select
Communicationport ethernet:IEEE802.3
The host Gross weight 59kg
volume 70*60*65cm3
Oscillation device Gross weight 42kg
volume 61*46*57cm3
Air gas generator Gross weight 42kg
volume 65*40*77cm3

Hydrogen

generator

Gross weight 21kg
volume 53*36*55cm3
Gas cylinders Gross weight 17kg
volume 96*21.5*21.5cm3

Detector specification

Hydrogen flame ionization detector (FID)
Detection limit ≤3×10-12g/s (n-hexadecane/isooctane)
baseline noise ≤5×10-14A
baseline drift ≤1×10-13A/30min
Linear range ≥107
Thermal conductivity detector(TCD)  
Sensitivity s≥10000mV.ml/mg(benzene/toluene)(magnification 1 2 4 8 times optional)
Detector number five,FID、TCD、ECD、FPD、NPD(optional)
baseline noise ≤20μV
baseline drift ≤30μV/30min
Linear range ≥105
Electron capture detector(ECD)
Detection limit ≤1×10-14g/ml(propane-h66/isooctane)
baseline noise ≤0.03mV
baseline drift ≤0.2mV/30min
Linear range ≥104
Source ni63
Detection limit (S)≤2×10-11g/s 、(P)≤1×10-12g/s(methyl parathion/anhydrous ethanol)
baseline noise ≤3×10-13A
baseline drift ≤2×10-12A/30min
Linear range sulfur≥103、in p≥104

Quality Keep Improving - Service Pursuing Perfection Pre-sales service commitment Provide professional consulting service; dedicated salesman and professional technical engineer to answer customer questions Ensure customer get the detailed information about the product in hand Reasonable price. Quotation stamped and confirmed by Manager

Welcome customers visit on-purchase service commitment The contract and the technical agreement to sign by both parties Being trustworthy, follow the requirements and ensure successful implementation of signed contracts and technical agreements Focus on communication, actively communicate with users, take notes of user’s questions and schedule, provide the necessary technical support. Move quick and efficient, professional on delivery, installation, debugging, training and others

After-sales service commitment Professional after-sales service department; ask and listen to customer’s feedback about the products and take records. Product guaranty: one year free warranty, life long maintenance, since the delivery of the product Provide solutions within 24 hours when there is problems feedback from customer. Professional research and development team.

Recommended products

Email:
whgdmk@yeah.net
Skype:
Emma Lei
live:.cid.d703d549beaabb3e
电话:
+8618164248846